Everything you need
– the most specialized EDOF lens portfolio in Bulgaria.
Monofocal implants
Still the standard in cataract surgery, offering proven safety and predictability of the result. They are the ideal solution for routine intervention, providing crystal clear vision at a distance
Refractive EDOF implants
Optical technology that directly refracts and focuses light for precise vision correction, providing a stable and predictable visual outcome.
Spherically aberrated EDOF implants
A specialized aspheric design that adjusts or eliminates spherical aberration (SA), delivering depth of focus and functional intermediate vision.
Trifocal diffractive implants
The diffractive grating splits light into focal points covering all three key distances, contributing to complete spectacle independence.
Everything you need
– the most specialized EDOF portfolio of intraocular lenses (IOLs) in Bulgaria.
Refractive EDOF implants
Optical technology that directly refracts and focuses light for precise vision correction, providing a stable and predictable visual outcome.
Spherical Aberration EDOF Implants
A specialized aspheric design that adjusts or eliminates spherical aberration (SA), delivering depth of focus and functional intermediate vision.
Diffractive Implants
The diffractive grating splits light into focal points covering all three key distances, contributing to complete spectacle independence.
Teleon Surgical is a leading German manufacturer and global pioneer in ophthalmology, headquartered in Speller, Germany, with over 30 years of experience in developing innovative surgical solutions. The company operates its own high-tech production facilities in Germany and the Netherlands, focusing entirely on the highest standards of quality in ophthalmic microsurgery. Their intraocular lenses are categorized into three main families: LENTIS, ACUNEX and FEMTIS.
Teleon Surgical is a leading German manufacturer and global pioneer in ophthalmology, headquartered in Speller, Germany, with over 30 years of experience in developing innovative surgical solutions. The company operates its own high-tech production facilities in Germany and the Netherlands, focusing entirely on the highest standards of quality in ophthalmic microsurgery. Their intraocular lenses are categorized into three main families: LENTIS, ACUNEX and FEMTIS.
LENTIS Comfort
The proven design is precisely adapted for distance and intermediate vision, meeting the high demands of patients and maximum safety. Also available is Comfort Toric for astigmatism correction. Over 10 years of experience in Bulgaria
Patented material HydroSmart® consisting of hydrophilic acrylate with a hydrophobic surface coating, with a water content of 25% and UV blocker, monoblock design. Refractive index 1.46
Optics 6mm; aspheric; SA neutral; 11mm overall diameter
|
|
Optical |
Ultrasound |
|
SRK/T |
118.5 |
118.0 |
|
Holladay 1: Sf |
1.47 |
- |
|
Barrett: LF |
1.62 |
- |
|
Haigis4: a0; a1; a2 |
0.95; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.21 |
- |
Cylinder: T0 - 0.75D; T1 - 1.50D; T2 - 2.25D; T3 - 3.00D; T4 - 3.75D; T5 - 4.50D; T6 - 5.25D;
Implantation: Medicel Viscoject 2.2mm (all diopters)
Pedrotti, E., Mastropasqua, R., Bonetto, J., Demasi, C., Aiello, F., Nucci, C., Mariotti, C., & Marchini, G. (2017). Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens. International Ophthalmology, 38(4), 1709–1716.
Teleon Surgical B.V. LENTIS® – User manual and technical information (ref. No QF2210v2-BGR
LENTIS Comfort
The proven design is precisely adapted for distance and intermediate vision, meeting the high demands of patients and ensuring maximum safety. Also available is Comfort Toric for astigmatism correction. Over 10 years of experience in Bulgaria
Patented material HydroSmart® consisting of hydrophilic acrylate with a hydrophobic surface coating, with a water content of 25% and UV blocker, monoblock design. Refractive index 1.46
Optics 6mm; aspheric; SA neutral; 11mm overall diameter
|
|
Optical |
Ultrasound |
|
SRK/T |
118.5 |
118.0 |
|
Holladay 1: Sf |
1.47 |
- |
|
Barrett: LF |
1.62 |
- |
|
Haigis4: a0; a1; a2 |
0.95; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.21 |
- |
Cylinder: T0 - 0.75D; T1 - 1.50D; T2 - 2.25D; T3 - 3.00D; T4 - 3.75D; T5 - 4.50D; T6 - 5.25D;
Implantation: Medicel Viscoject 2.2mm (all diopters)
Pedrotti, E., Mastropasqua, R., Bonetto, J., Demasi, C., Aiello, F., Nucci, C., Mariotti, C., & Marchini, G. (2017). Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens. International Ophthalmology, 38(4), 1709–1716.
Teleon Surgical B.V. LENTIS® – User manual and technical information (ref. No QF2210v2-BGR


LENTIS Mplus MF20 and LENTIS Mplus MF30
Provide clear vision at all distances for patients with presbyopia (age-related farsightedness). If your patient suffers from both astigmatism and presbyopia, the toric lenses LENTIS Mplus Toric corrects both visual defects simultaneously.
MF20(2D addition; ≈ vision at 50cm) - desk activities, cooking, working with tools, working at a cash register
MF30(3D addition; ≈ vision at 33cm) - true near vision - reading small print, sewing, knitting, jewelry making, and others
The combination of MF20 and MF30 (in the dominant eye) creates a visual system that covers distance, intermediate, and near distances, allowing the patient to achieve a high degree of visual independence without classic trifocal optics.
Patented material HydroSmart® consisting of hydrophilic acrylate with a hydrophobic surface coating, with a water content of 25% and UV blocker, monoblock design.
Optics 6mm; aspheric; SA neutral
|
|
Optical |
Ultrasound |
|
SRK/T |
118.5 |
118.0 |
|
Holladay 1: Sf |
1.47 |
- |
|
Barrett: LF |
1.62 |
- |
|
Haigis4: a0; a1; a2 |
0.95; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.21 |
- |
Standard Cylinder: T0 - 0.75D; T1 - 1.50D; T2 - 2.25D; T3 - 3.00D; T4 - 3.75D; T5 - 4.50D; T6 - 5.25D;
Custom Cylinder: from 0.5D to 10.0D (in 0.01D), precise manufacturing according to the meridian of astigmatism (accuracy up to 1°); manufacturing 30 days
Implantation: Medicel Viscoject 2.2mm (all diopters)
Ye, L., Chen, T., Hu, Z., Yang, Q., Su, Q., & Li, J. (2021). Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses. Annals of Translational Medicine, 9(2), 144.
LENTIS Mplus MF20 and LENTIS Mplus MF30
Provide clear vision at all distances for patients with presbyopia (age-related farsightedness). If your patient suffers from both astigmatism and presbyopia, the toric lenses LENTIS Mplus Toric correct both visual defects simultaneously.
MF20(2D addition; ≈ vision at 50cm) - desk activities, cooking, working with tools, working at a cash register
MF30(3D addition; ≈ vision at 33cm) - true near vision - reading small print, sewing, knitting, jewelry making, and others
The combination of MF20 and MF30 (in the dominant eye) creates a visual system that covers distance, intermediate, and near distances, allowing the patient to achieve a high degree of visual independence without classic trifocal optics.
Patented material HydroSmart® consisting of hydrophilic acrylate with a hydrophobic surface coating, with a water content of 25% and UV blocker, monoblock design.
Optics 6mm; aspheric; SA neutral
|
|
Optical |
Ultrasound |
|
SRK/T |
118.5 |
118.0 |
|
Holladay 1: Sf |
1.47 |
- |
|
Barrett: LF |
1.62 |
- |
|
Haigis4: a0; a1; a2 |
0.95; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.21 |
- |
Standard Cylinder: T0 - 0.75D; T1 - 1.50D; T2 - 2.25D; T3 - 3.00D; T4 - 3.75D; T5 - 4.50D; T6 - 5.25D;
Custom Cylinder: from 0.5D to 10.0D (in 0.01D), precise manufacturing according to the meridian of astigmatism (accuracy up to 1°); manufacturing 30 days
Implantation: Medicel Viscoject 2.2mm (all diopters)
Ye, L., Chen, T., Hu, Z., Yang, Q., Su, Q., & Li, J. (2021). Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses. Annals of Translational Medicine, 9(2), 144.


LENTIS MplusX
Distributes more light energy for near, therefore recommended for myopes. If your patient suffers from both astigmatism and presbyopia, the toric lenses LENTIS MplusX Toric correct both visual defects simultaneously.
MplusX distributes more light energy for near, therefore recommended for myopes, which require excellent vision at close distance (≈ 33cm), but also independence from glasses. It is recommended that the calculation of the IOL be towards a slightly positive refractive result, up to about +0.50 D.
Patented material HydroSmart® consisting of hydrophilic acrylate with a hydrophobic surface coating, with a water content of 25% and UV blocker, monoblock design.
distance, but also an additional element - additive paraxial asphericity (APA). This addition at the back of the implant uses spherical ablations aimed at adding intermediate distance to the optics' performance. In practice, MplusX is an implant that combines 2 types of EDOF technology.
It uses rotational-asymmetric sector technology without diffractive rings, which provides full focus without light loss and minimal glare.
Optics 6mm; aspheric; SA neutral
|
|
Optical |
Ultrasound |
|
SRK/T |
118.5 |
118.0 |
|
Holladay 1: Sf |
1.47 |
- |
|
Barrett: LF |
1.62 |
- |
|
Haigis4: a0; a1; a2 |
0.95; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.21 |
- |
Standard Cylinder: T0 - 0.75D; T1 - 1.50D; T2 - 2.25D; T3 - 3.00D; T4 - 3.75D; T5 - 4.50D; T6 - 5.25D;
Custom Cylinder: from 0.5D to 10.0D (in 0.01D), precise manufacturing according to the meridian of astigmatism (accuracy up to 1°); manufacturing 30 days
Implantation: Medicel Viscoject 2.2mm (all diopters)
Kohnen, T., Hemkeppler, E., Herzog, M., Schönbrunn, S., DeLorenzo, N., Petermann, K., & Böhm, M. (2018). Visual outcomes after implantation of a segmental refractive multifocal intraocular lens following cataract surgery. American Journal of Ophthalmology, 191, 156–165.

LENTIS Mplus
MplusX allocates more light energy for near vision, making it the recommended choice for myopic patients. If your patient suffers from both astigmatism and presbyopia, LENTIS MplusX Toric lenses correct both refractive errors simultaneously.
MplusX distributes more light energy for near, therefore recommended for myopes, which require excellent vision at close distance (≈ 33cm), but also independence from glasses. It is recommended that the calculation of the IOL be towards a slightly positive refractive result, up to about +0.50 D.
Patented material HydroSmart® consisting of hydrophilic acrylate with a hydrophobic surface coating, with a water content of 25% and UV blocker, monoblock design.
distance, but also an additional element - additive paraxial asphericity (APA). This addition at the back of the implant uses spherical ablations aimed at adding intermediate distance to the optics' performance. In practice, MplusX is an implant that combines 2 types of EDOF technology.
It uses rotational-asymmetric sector technology without diffractive rings, which provides full focus without light loss and minimal glare.
Optics 6mm; aspheric; SA neutral
|
|
Optical |
Ultrasound |
|
SRK/T |
118.5 |
118.0 |
|
Holladay 1: Sf |
1.47 |
- |
|
Barrett: LF |
1.62 |
- |
|
Haigis4: a0; a1; a2 |
0.95; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.21 |
- |
Standard Cylinder: T0 - 0.75D; T1 - 1.50D; T2 - 2.25D; T3 - 3.00D; T4 - 3.75D; T5 - 4.50D; T6 - 5.25D;
Custom Cylinder: from 0.5D to 10.0D (in 0.01D), precise manufacturing according to the meridian of astigmatism (accuracy up to 1°); manufacturing 30 days
Implantation: Medicel Viscoject 2.2mm (all diopters)
Kohnen, T., Hemkeppler, E., Herzog, M., Schönbrunn, S., DeLorenzo, N., Petermann, K., & Böhm, M. (2018). Visual outcomes after implantation of a segmental refractive multifocal intraocular lens following cataract surgery. American Journal of Ophthalmology, 191, 156–165.

Acunex Quantum
Refractive implant type MonoEDOF simultaneously maintains excellent contrast sensitivity, quality distance vision, and a low risk of dysphotopsia. Stay tuned for Quantum toric
.
6 mm; aspheric posterior surface; -0.130 µm SA (IOL); 0° haptic angulation
|
|
Optical |
Ultrasound |
|
SRK/T |
119.5 |
119.1 |
|
Holladay 1: Sf |
2.07 |
- |
|
Barrett: LF |
2.15 |
- |
|
Haigis4: a0; a1; a2 |
1.64; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.84 |
- |
Standard Cylinder: Coming soon
Implantation: Medicel Viscoject 2.0 / 2.1 / 2.2 mm (all diopters)

Acunex Quantum
Refractive implant type MonoEDOF simultaneously maintains excellent contrast sensitivity, quality distance vision, and low risk of dysphotopsia. Expect Quantum toric soon
.
6 mm; aspheric posterior surface; -0.130 µm SA (IOL); 0° haptic angulation
|
|
Optical |
Ultrasound |
|
SRK/T |
119.5 |
119.1 |
|
Holladay 1: Sf |
2.07 |
- |
|
Barrett: LF |
2.15 |
- |
|
Haigis4: a0; a1; a2 |
1.64; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.84 |
- |
Standard Cylinder: Coming soon
Implantation: Medicel Viscoject 2.0 / 2.1 / 2.2 mm (all diopters)

Acunex Vario and VarioMAX
They provide clear vision at all distances for presbyopic patients. If your patient suffers from both astigmatism and presbyopia,Vario Toric and VarioMAX Toric lenses correct both refractive errors simultaneously.
VarioMAX is the hydrophobic equivalent of LENTIS MF30, offering greater convenience and confidence for the surgeon. With a +3.0 D addition (≈ 33 cm reading distance), it is suited for patients who rely on stronger near vision—such as tailors, watchmakers, dental technicians, electricians, and beauticians.
The mix-and-match combination of Vario and VarioMAX (placed in the dominant eye) creates a visual system covering distance, intermediate, and near ranges, allowing patients to achieve high spectacle independence without using conventional trifocal optics.
6 mm; aspheric posterior surface; no SA (IOL); 0° haptic angulation
|
|
Optical |
Ultrasound |
|
SRK/T |
119.5 |
119.1 |
|
Holladay 1: Sf |
2.07 |
- |
|
Barrett: LF |
2.15 |
- |
|
Haigis4: a0; a1; a2 |
1.64; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.84 |
- |
Standard Cylinder: T0 – 0.75 D; T1 – 1.50 D; T2 – 2.25 D; T3 – 3.00 D;
Implantation: Medicel Viscoject 2.0 / 2.1 / 2.2 mm (all diopters)
Wanten, J. C., Bauer, N. J. C., Berendschot, T. T. J. M., Van Den Biggelaar, F. J. H. M., & Nuijts, R. M. M. A. (2025). Two novel extended depth-of-focus intraocular lenses targeted for mini-monovision: a prospective randomized controlled trial. American Journal of Ophthalmology.
Teleon Surgical BV, (2023), Tech AcuNex VarioMax and AcuNex VarioMax toric; The varifocal premium IOL for presbyopia and astigmatism; Duo* [brochure]

Acunex Vario and VarioMAX
Provide clear vision at all distances for patients with presbyopia. If your patient suffers from both astigmatism and presbyopia, the toric lenses Vario toric and VarioMAX Toric correct both visual defects simultaneously.
VarioMAX is the hydrophobic equivalent of LENTIS MF30, offering greater convenience and confidence for the surgeon. With a +3.0 D addition (≈ 33 cm reading distance), it is suited for patients who rely on stronger near vision—such as tailors, watchmakers, dental technicians, electricians, and beauticians.
The mix-and-match combination of Vario and VarioMAX (placed in the dominant eye) creates a visual system covering distance, intermediate, and near ranges, allowing patients to achieve high spectacle independence without using conventional trifocal optics.
6 mm; aspheric posterior surface; no SA (IOL); 0° haptic angulation
|
|
Optical |
Ultrasound |
|
SRK/T |
119.5 |
119.1 |
|
Holladay 1: Sf |
2.07 |
- |
|
Barrett: LF |
2.15 |
- |
|
Haigis4: a0; a1; a2 |
1.64; 0.4; 0.1 |
- |
|
Hoffer Q: pACD |
5.84 |
- |
Standard Cylinder: T0 – 0.75 D; T1 – 1.50 D; T2 – 2.25 D; T3 – 3.00 D;
Implantation: Medicel Viscoject 2.0 / 2.1 / 2.2 mm (all diopters)
Wanten, J. C., Bauer, N. J. C., Berendschot, T. T. J. M., Van Den Biggelaar, F. J. H. M., & Nuijts, R. M. M. A. (2025). Two novel extended depth-of-focus intraocular lenses targeted for mini-monovision: a prospective randomized controlled trial. American Journal of Ophthalmology.
Teleon Surgical BV, (2023), Tech AcuNex VarioMax and AcuNex VarioMax toric; The varifocal premium IOL for presbyopia and astigmatism; Duo* [brochure]

AST Products, Inc. is an American biotechnology company founded in 1989 and headquartered in Billerica (Massachusetts, USA). It is a global leader in surface technologies and medical device manufacturing, renowned for its patented innovations in enhancing biocompatibility and developing high-end ophthalmic products.
AST Vision Care Inc. is an American biotechnology company founded in 1989, headquartered in Billerica (Massachusetts, USA). It is a global leader in surface technologies and the manufacturing of medical devices, known for its patented innovations to improve biocompatibility and the development of high-quality ophthalmic products.
Asqelio Monofocal
The monofocal intraocular lens is a precision implant that provides crystal-clear, high-contrast vision at a single fixed distance—most commonly for distance vision. It represents an exceptionally reliable solution for routine cataract surgery. The Asqelio Monofocal Toric model is also available.
Soft hydrophobic acrylic (glistening-free, with water content <0.5%), UV blocker: 99% UVB and 90% UVA. Refractive index: 1.50. Abbe number: 50; Monoblock - 13mm overall diameter
|
|
Optical |
Ultrasound |
|
SRK/T |
119.33 |
119.1 |
|
Holladay 1: Sf |
1.99 |
- |
|
Barrett: LF |
2.09 |
- |
|
Haigis: a0 |
1.54 |
- |
|
Hoffer Q: pACD |
5.75 |
- |
Cylinder: from +1.00 D to +6.00 D in 0.5 D steps
Implantation: through a 2.2 mm incision via bioli™ or another injector

Asqelio™ Monofocal
The monofocal intraocular implant is a precise lens that provides crystal clear and high-contrast vision at a specific distance — most often for distance vision. It is an extremely reliable solution for routine cataract surgery. Available with/without a blue light filter, as well as Asqelio Monofocal Toric
Soft hydrophobic acrylic (glistening-free, with water content <0.5%), UV blocker: 99% UVB and 90% UVA. Refractive index: 1.50. Abbe number: 50; Monoblock - 13mm overall diameter
|
|
Optical |
Ultrasound |
|
SRK/T |
119.33 |
119.1 |
|
Holladay 1: Sf |
1.99 |
- |
|
Barrett: LF |
2.09 |
- |
|
Haigis: a0 |
1.54 |
- |
|
Hoffer Q: pACD |
5.75 |
- |
Cylinder: from +1.00 D to +6.00 D in 0.5 D steps
Implantation: through a 2.2 mm incision via bioli™ or another injector

Asqelio Pluris
Refractive MonoEDOF implant that simultaneously maintains excellent contrast sensitivity and high-quality distance vision, along with functional intermediate vision (70–80 cm). Asqelio Pluris Toric is also available.
Soft hydrophobic acrylic (glistening-free, with water content <0.5%), UV blocker: 99% UVB and 90% UVA. Refractive index: 1.50. Abbe number: 50; Monoblock - 13mm overall diameter
6mm optics; bi-aspheric optical design; SA= -0.270 µm to neutralize spherical aberrations from the cornea; 5° angulation of the haptics
|
|
Optical |
Ultrasound |
|
SRK/T |
119.33 |
119.1 |
|
Holladay 1: Sf |
1.99 |
- |
|
Barrett: LF |
2.09 |
- |
|
Haigis: a0 |
1.54 |
- |
|
Hoffer Q: pACD |
5.75 |
- |
Cylinder: from +1.00 D to +6.00 D in 0.5 D steps
Implantation: through a 2.2 mm incision via bioli™ or another injector

Asqelio™ Pluris™
Refractive implant type MonoEDOF simultaneously maintains excellent contrast sensitivity, quality distance vision with functional vision at intermediate distances (70-80cm). Available with/without a blue light filter, as well as Asqelio Pluris Toric
Soft hydrophobic acrylic (glistening-free, with water content <0.5%), UV blocker: 99% UVB and 90% UVA. Refractive index: 1.50. Abbe number: 50; Monoblock - 13mm overall diameter
6mm optics; bi-aspheric optical design; SA= -0.270 µm to neutralize spherical aberrations from the cornea; 5° angulation of the haptics
|
|
Optical |
Ultrasound |
|
SRK/T |
119.33 |
119.1 |
|
Holladay 1: Sf |
1.99 |
- |
|
Barrett: LF |
2.09 |
- |
|
Haigis: a0 |
1.54 |
- |
|
Hoffer Q: pACD |
5.75 |
- |
Cylinder: from +1.00 D to +6.00 D in 0.5 D steps
Implantation: through a 2.2 mm incision via bioli™ or another injector

Asqelio EDOF
Refractive standard type EDOF that simultaneously maintains excellent contrast sensitivity and high-quality distance vision, along with functional intermediate vision (50–60 cm). Available with or without a blue light filter, as well as the Asqelio EDOF Toric model.
Soft hydrophobic acrylic (glistening-free, with water content <0.5%), UV blocker: 99% UVB and 90% UVA. Refractive index: 1.50. Abbe number: 50; Monoblock - 13mm overall diameter
6mm optics; bi-aspheric optical design; SA= -0.270 µm to neutralize spherical aberrations from the cornea; 5° angulation of the haptics
|
|
Optical |
Ultrasound |
|
SRK/T |
119.33 |
119.1 |
|
Holladay 1: Sf |
1.99 |
- |
|
Barrett: LF |
2.09 |
- |
|
Haigis: a0 |
1.54 |
- |
|
Hoffer Q: pACD |
5.75 |
- |
Cylinder: from +1.00 D to +6.00 D in 0.5 D steps
Implantation: through a 2.2 mm incision via bioli™ or another injector

Asqelio™ EDOF
Refractive implant type classical EDOF simultaneously maintains excellent contrast sensitivity, quality distance vision with functional vision at medium distance (50-60cm). Available with/without blue light filter, as well as Asqelio EDOF Toric
Soft hydrophobic acrylic (glistening-free, with water content <0.5%), UV blocker: 99% UVB and 90% UVA. Refractive index: 1.50. Abbe number: 50; Monoblock - 13mm overall diameter
6mm optics; bi-aspheric optical design; SA= -0.270 µm to neutralize spherical aberrations from the cornea; 5° angulation of the haptics
|
|
Optical |
Ultrasound |
|
SRK/T |
119.33 |
119.1 |
|
Holladay 1: Sf |
1.99 |
- |
|
Barrett: LF |
2.09 |
- |
|
Haigis: a0 |
1.54 |
- |
|
Hoffer Q: pACD |
5.75 |
- |
Cylinder: from +1.00 D to +6.00 D in 0.5 D steps
Implantation: through a 2.2 mm incision via bioli™ or another injector

Asqelio Trifocal
Diffractive trifocal implant providing crystal-clear vision at all distances—for near reading, screen work, and distance vision. Asqelio Trifocal delivers complete independence from glasses for all daily activities. Asqelio Trifocal Toric is also available.
For patients seeking maximum independence from glasses — reading menus, working at a screen, driving, and clear vision at a distance, all combined in one lens for the entire spectrum of daily activities.
Soft hydrophobic acrylic (glistening-free, with water content <0.5%), UV blocker: 99% UVB and 90% UVA. Refractive index: 1.50. Abbe number: 50; Monoblock - 13mm overall diameter
6mm optics; bi-aspheric optical design; SA= -0.270 µm to neutralize spherical aberrations from the cornea; 5° angulation of the haptics
|
|
Optical |
Ultrasound |
|
SRK/T |
119.46 |
119.23 |
|
Holladay 1: Sf |
2.10 |
- |
|
Barrett: LF |
2.15 |
- |
|
Haigis: a0 |
1.66 |
- |
|
Hoffer Q: pACD |
5.87 |
- |
Cylinder: from +1.00 D to +6.00 D in 0.5 D steps
Implantation: through a 2.2 mm incision via bioli™ or another injector
DOI: 10.2147/OPTH.S400136

Asqelio™ Trifocal
A diffractive trifocal implant that provides crystal clear vision at all distances — for reading up close, working at a screen, and distance vision. Asqelio Trifocal offers complete independence from glasses for all daily activities. Available with/without a blue light filter, as well as Asqelio Trifocal Toric
For patients seeking maximum independence from glasses — reading menus, working at a screen, driving, and clear vision at a distance, all combined in one lens for the entire spectrum of daily activities.
Soft hydrophobic acrylic (glistening-free, with water content <0.5%), UV blocker: 99% UVB and 90% UVA. Refractive index: 1.50. Abbe number: 50; Monoblock - 13mm overall diameter
6mm optics; bi-aspheric optical design; SA= -0.270 µm to neutralize spherical aberrations from the cornea; 5° angulation of the haptics
|
|
Optical |
Ultrasound |
|
SRK/T |
119.46 |
119.23 |
|
Holladay 1: Sf |
2.10 |
- |
|
Barrett: LF |
2.15 |
- |
|
Haigis: a0 |
1.66 |
- |
|
Hoffer Q: pACD |
5.87 |
- |
Cylinder: from +1.00 D to +6.00 D in 0.5 D steps
Implantation: through a 2.2 mm incision via bioli™ or another injector
DOI: 10.2147/OPTH.S400136
